ISO1211DR
Product Specifications
ISO1211DR
Texas Instruments — Power Management & Signal Chain
Product Overview
The ISO1211DR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
ISO1211DR: single-channel isolated 24 V digital input receiver in an 8-pin SOIC
ISO1211DR is an isolated digital input receiver that replaces the optocoupler and the field side supply on a 24 V input in a SOIC body of 8 pins. The part takes a 24 V field signal through one external resistor and hands the controller a clean logic level across a 2500 V RMS barrier. It meets IEC 61131-2 Type 1, 2 and 3 characteristics with a current limit of 2.2 to 2.47 milliamps for a Type 3 input, and no supply is needed on the field side.
Order code and package
| Order code | ISO1211DR |
| Function | isolated 24 V digital input receiver, single channel |
| Package | SOIC, 8 pins |
| Standard | IEC 61131-2 Type 1, 2 and 3 for 24 V isolated inputs |
| Input range | 9 V to 300 V DC and AC with external resistors |
| Current limit | 2.2 to 2.47 milliamps for Type 3, adjustable to 6.5 milliamps |
| Field side supply | none required |
| Reverse polarity | protected to minus 60 V |
| Isolation | 2500 V RMS per UL 1577 |
| Diagnostics | wire break detection available |
| Supply | 2.25 V to 5.5 V on the logic side |
| Temperature range | minus 40 to plus 125 C |
Electrical parameters that decide the application
| Output | CMOS logic level, push pull |
| Threshold | set by the external resistor and the internal current limit |
| Power dissipation | set by the current limit, not by the input voltage |
| Certifications | VDE 0884-17 conformity, UL 1577, IEC 60950-1, IEC 62368-1, IEC 61010-1, GB 4943.1 |
| Channel count | one in this body, two in the ISO1212 |
| Functional safety | documentation available for system level safety work |
| Propagation | fast enough for counter inputs, specified in the switching table |
| Filtering | the current limit acts with the external capacitor to reject contact bounce |
Points to check before this part goes on a BOM
The current limit is what separates this part from an optocoupler front end. At 2.2 milliamps for a Type 3 input, a 24 V field signal dissipates about 53 milliwatts in the external resistor and very little in the receiver, so eight inputs on one module no longer heat the enclosure the way eight optocouplers did.
Because the limit is a current rather than a voltage threshold, a 110 V DC input needs only a larger external resistor, not a different receiver. That is how the same order code covers 9 V to 300 V, and it is why the resistor value has to be calculated for the actual field voltage rather than copied from a reference board.
Reverse polarity protection to minus 60 V means a miswired field cable does not destroy the input. The resistor still carries the fault current, so a wire fault that puts 24 V across the resistor for a long time is a resistor power rating question, not a receiver question.
Wire break detection works because a live input draws its limited current through the field loop. With no current the input reads low even when the switch is closed, which is the diagnostic that separates a broken wire from an open contact on a safety input.
Where this order code fits
PLC input modules, motor control cabinets and any board that has to read a 24 V sensor while its logic ground sits at a different potential order this code. Boards comparing it with a neighbouring part start from our Medical Device Components page, and boards replacing a part that has gone end of life start from the Component Lead Time Solutions page.
Questions buyers ask
Is an isolated field supply still needed? No. The field side draws its current from the 24 V signal itself, which is the reason the part removes the isolated DC to DC converter from the BOM.
Can it read an AC input? Yes, with external resistors sized for the AC voltage; the receiver rectifies through its input structure and the current limit holds the input current.
SUPERB holds and sources this Texas Instruments line for production and repair demand, quoted against the exact ordering string with date codes, packing and country of origin stated on the offer. When a line is moving, the Incoming Inspection Plan page sets out the checks that keep a substitute from failing on the bench.