INA241B5IDDFR
Product Specifications
INA241B5IDDFR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA241B5IDDFR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA241B5IDDFR: 200 V/V for the low current end
The INA241B5IDDFR is the 200 V/V member of the B accuracy tier in the 8 pin SOT-23-THIN body. It combines the widest gain in the family with the wider offset window: 150 uV maximum offset and 0.1 percent maximum gain error, against 10 uV and 0.01 percent on the A tier. The input stage is unchanged, minus 5 V to 110 V operational, 120 V survival, 166 dB typical DC rejection, 1.1 MHz bandwidth.
The combination is less odd than it looks. A 200 V/V front end is for a low current channel, and a low current channel is usually a threshold rather than a measurement: a leakage detector, a precharge completion flag, a solenoid holding current monitor. All of those compare against a limit, and a limit with 30 percent margin does not need a 10 uV offset.
Key data for the INA241B5IDDFR
| Gain | 200 V/V fixed, the highest of the five B tier gains |
| Common mode | Minus 5 V to 110 V operational, minus 20 V to 120 V survival, independent of the 2.7 V to 20 V supply |
| Accuracy | Offset 150 uV maximum, 0.5 uV per degree, gain error 0.1 percent maximum, gain drift 5 ppm per degree |
| Rejection | 166 dB DC typical, 104 dB at 100 kHz, 89 dB at 1 MHz, with PWM rejection to 125 kHz |
| Speed | 1.1 MHz at all gains, 8 V per microsecond slew, 1 us settling to 1 percent |
| Supply | 2.7 V to 20 V, 2.5 mA typical and 3 mA maximum, minus 40 C to 125 C |
Body, marking and reel data
| Body | DDF, 8 pin SOT-23-THIN at 2.9 mm by 2.8 mm, shared with every other gain in the family |
| Reel | 3000 pieces on a large reel at moisture level 1, unlimited floor life |
| Finish | NIPDAU plated leads, lead free reflow compatible at 260 C |
| Marking | 2PQ3 on this gain and body, no tier marker |
| Output swing | The usable input window is set by the output swing divided by 200, about 7.5 mV on a 3.3 V rail |
Where a 200 V/V threshold channel fits
A precharge completion flag is the clean example. The resistor charges a bus capacitor and the current falls from amps to milliamps; the controller needs to know when the current is below a threshold before closing the contactor. At 200 V/V with a 10 milliohm shunt, 50 mA produces 100 mV at the output, which is 30 times the offset and far above any comparator hysteresis the host applies.
The same channel fails as a measurement. The 150 uV offset is 750 uV referred to the shunt, which is 75 mA through a 10 milliohm shunt, so any reading below about a quarter of an amp has to be treated as an estimate. Where the channel needs both the flag and the number, the split is a comparator channel on the B tier and a measurement channel on the A tier, which is cheaper than paying for two A tier parts. The B tier also removes the temptation to calibrate at the end of the line, which on a high volume board is a test station the programme does not have to buy. A gain change inside the same tier is also easier to approve than a change of part number, because the reel, the body and the qualification record all stay the same. Where a build is being resourced from an analog output amplifier to this family, our amplifier cross reference note lists the analog devices that share the same front end behaviour, and our strategic sourcing note covers how we hold both tiers on a single annual agreement.
Buyer questions on the INA241B5IDDFR
Why pair the highest gain with the wider tier? Because the applications that need 200 V/V are thresholds rather than meters, and a threshold does not benefit from a tighter offset.
How much current does the channel draw? 2.5 mA typical from the 2.7 V to 20 V rail, independent of gain, so a low current measurement does not cost a low power front end.
Can the output drive an ADC directly? Yes, the output is a voltage that swings to within tens of millivolts of either rail, and the reference pins set where zero current sits in that swing.
Availability and ordering notes
The DDF rows are active at 3000 pieces on a large reel with NIPDAU at moisture level 1. The gain family shares one ordering table across three bodies and two tiers, and this revision prints the package and quantity columns shifted by a row, so the decode is the only trustworthy guide to what a given string ships as. Where a programme uses several gains from the family, we build a single line item with sub lines per gain and keep the tier separation explicit on the supplier scorecard, because a mis-shipped tier is the one error that passes incoming inspection and fails on the bench.