INA190A4IDDFR
Product Specifications
INA190A4IDDFR
Texas Instruments — Power Management & Signal Chain
Product Overview
The INA190A4IDDFR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
INA190A4IDDFR: the 200 V/V precision member on a large reel
INA190A4IDDFR is the 200 V/V member of the precision current sense family in the eight pin thin body on a 3000 piece large reel. At this gain a 5 milliohm shunt carrying 1 amp produces 1 volt, and the same part reads a battery discharge of 5 amps through a 1 milliohm shunt as the same 1 volt.
Both pins are present, so the channel can be bidirectional and can sleep. The offset is 15 microvolts maximum, which at 200 V/V is 3 millivolts at the output, and the drift is 80 nanovolts per degree, which over a 100 degree excursion adds 8 microvolts at the input. Those two rows are what a precision channel at this gain is actually buying, and they are the reason to take this family rather than the cheaper one.
INA190A4IDDFR as the vendor document publishes it
| Gain | 200 V/V fixed |
| Gain error | 0.06 per cent typical, 0.3 per cent maximum |
| Gain error drift | 2 ppm per degree typical, 7 maximum |
| Nonlinearity | 0.01 per cent typical of full scale |
| Offset voltage | 3 microvolts typical, 15 microvolts maximum, referred to the input |
| Offset drift | 10 nanovolts per degree typical, 80 maximum |
| Input bias current | 0.5 nanoamps typical, 3 nanoamps maximum |
| Input offset current | 70 picoamps typical |
| Common mode rejection | 132 dB minimum, 150 typical, over minus 40 to plus 125 degrees |
| Power supply rejection | 1 microvolt per volt typical, 5 maximum |
| Reference rejection | 0.25 microvolts per volt typical, 3 maximum at this gain |
| Common mode range | minus 0.2 volts to plus 40 volts, independent of the supply |
| Supply range | 1.7 volts to 5.5 volts |
| Quiescent current | 50 microamps typical, 65 maximum when enabled |
| Shutdown current | 100 nanoamps maximum |
| Bandwidth | between 37 and 35 kHz at this gain, from the family rows printed at 45, 37 and 35 kHz |
| Slew rate | 0.3 volts per microsecond |
| Settling to 1 per cent | 30 microseconds from a current step |
| Voltage noise density | published as a typical curve, no limit row |
| Swing to the positive rail | 20 millivolts typical, 40 maximum into 10 kohm |
| Swing to ground | 0.05 millivolts typical, 1 maximum |
| Zero current output | 2 millivolts typical at this gain, 4 maximum |
| Stable load capacitance | 1 nanofarad |
| Temperature range | minus 40 to plus 125 degrees |
| Vendor status | active, 3000 piece large reel |
| Catalogue code | INA190A4IDDFR |
| Vendor string | INA190A4IDDFR |
| Body | SOT-23 thin, DDF, eight pin |
| Moisture level | level 1, 260 degrees, no floor life limit |
| Direction | bidirectional, reference pin available |
Gain error that widens with the gain option
The gain error of INA190A4IDDFR is binned by option rather than published once: 0.04 per cent typical and 0.2 maximum at 25 V/V, 0.06 and 0.3 at 50, 100 and 200 V/V, and 0.08 and 0.4 at 500 V/V, with 2 and 7 ppm per degree of drift across the family.
That progression is not an accident of sorting. The same resistor network that sets 25 V/V sets 500 V/V, and the error of each element is multiplied by the gain it contributes to, so the highest gain carries the largest window. The practical consequence is that a 500 V/V channel bought for a 100 microvolt shunt drop has four times the gain error of the 25 V/V channel, and if the accuracy requirement is tight the answer is a larger shunt with a lower gain rather than the highest gain the part offers.
Fifty microamps running and one hundred nanoamps asleep
Quiescent current on INA190A4IDDFR is 50 microamps typical and 65 maximum over temperature, and the shutdown current is 100 nanoamps maximum, with the enable pin bringing the part back in the time the document prints rather than in a fixed interval. On a battery instrument that samples once a second, the difference between 50 microamps and 100 nanoamps is the difference between a week of standby and a month.
Two details decide whether the saving is real. The output has to be allowed to settle after the enable, so the sampling window must start late enough for the amplifier and the converter to both be ready. And the leakage into the enabled input has to be small next to the shunt current, otherwise the monitor measures its own wake up. The enable threshold is 0.7 times the supply on the SOT-23 body with 100 millivolts of hysteresis, so a slow ramp on the control line does not chatter.
One hundred and thirty two decibels of rejection
Common mode rejection on INA190A4IDDFR is 132 dB minimum, twelve decibels better than the INA186, and the offset is quoted at 3 microvolts typical rather than at the 50 microvolt maximum of the cheaper part. On a 40 volt bus with 1 volt of switching ripple, 132 dB leaves 0.25 microvolts at the input, which is a sixth of the maximum offset and well under the noise of any bandwidth the part can pass.
The rejection is specified over the full minus 40 to plus 125 degree range rather than at room temperature, and that is the row a specification should carry. It is also the row that decides whether the monitor can sit on a phase node of a motor bridge with an 8 kHz chopper above it: at 132 dB the ripple is negligible, at 84 dB, which is what a cost optimised monitor publishes, the same ripple is 63 microvolts at the input and becomes visible on a small shunt.
Choosing between the INA186, the INA190 and the INA191
The three families share a topology and differ in one specification each. INA190A4IDDFR buys offset, 15 microvolts maximum against 50, and rejection, 132 dB against 120. The INA191 buys bias current, 100 picoamps against 500, in the smallest body of the three. The INA186 buys price and the wider choice of carriers, including the SC70 and the SOT-23 in both reel sizes.
The decision is therefore made by the error that dominates the channel. A microamp measurement through a large shunt is limited by bias and belongs to the INA191. A millamp measurement on a 40 volt bus is limited by rejection and belongs to this part. A channel where 1 per cent of full scale is good enough belongs to the INA186, and paying for the tighter grades there buys nothing the converter can see. Our amplifier cross reference page sets the three side by side, and the medical device components page covers the applications where the tighter offset is a requirement rather than an improvement.
The same architecture with the offset trimmed to fifteen microvolts
INA190A4IDDFR is the precision member of the same current sense family: 3 microvolts typical and 15 microvolts maximum of offset, with 10 and 80 nanovolts per degree of drift against the 50 microvolts and 0.5 microvolts per degree of the INA186. The bias current is the same 0.5 nanoamps typical, the supply window is the same 1.7 to 5.5 volts, and the common mode window is the same minus 0.2 to plus 40 volts.
What the tighter offset buys is range at the bottom. On a 10 milliohm shunt at a gain of 100, 15 microvolts of offset is 150 microamps of current error and 50 microvolts is 500 microamps, so a channel that has to resolve 1 amp from 1.1 amps needs the tighter part and a channel that has to resolve 10 from 11 does not. The price difference between the two families is the price of that bottom decade.
Three bodies, and the reference pin only in two of them
INA190A4IDDFR comes in the SC70, the SOT-23 thin body and a ten pin UQFN, and the UQFN is the one that exists for a reason other than size: it carries both the reference and the enable pins with more separation between the input and the supply, which matters on a board with a switching node nearby. The SOT-23 also carries both pins, and the SC70 carries the reference without the enable.
All three are specified from minus 40 to plus 125 degrees, all three run from 1.7 volts, and all three share the electrical table, so a change of body is a change of footprint and moisture level rather than of performance. The moisture levels differ, and that is the row to print on the order: the small plastic bodies carry a floor life after the bag is opened while the large reel rows of some bodies are listed at level 1 with no limit.
At 200 V/V the offset and the shunt tolerance both matter, and the comparison should be made at the working current rather than at full scale. Our amplifier cross reference page covers the options, and the traceability report page covers the grade evidence that travels with the reel.
Is the 200 V/V option slower than the others? The family's small signal bandwidth falls as the gain rises, with 45 kHz printed at 25 V/V and 35 kHz at 500 V/V; at 200 V/V it sits between those rows.
Does this part need a different reference for a bidirectional channel? It needs a reference between 0.1 volts and the supply minus 0.1 volts, and the reference rejection at this gain is 3 microvolts per volt maximum.