BQ25121AYFPR
Product Specifications
BQ25121AYFPR
Texas Instruments — Power Management & Signal Chain
Product Overview
The BQ25121AYFPR from Texas Instruments is a power management / signal chain IC delivering high efficiency, precision regulation, and robust protection. Texas Instruments (TI) is a global leader in analog ICs, power management solutions, and embedded processors.
Superb Automation partners with leading brands including Qorvo, TI, ADI, XILINX, NVIDIA, Intel, ST, MACOM, Renesas, and Coilcraft to provide complete BOM and supply-chain solutions.
Key Features
- High-efficiency power conversion with low quiescent current
- Wide input voltage range with precision output regulation
- Integrated over-current, over-temperature, and short-circuit protection
- Small footprint packaging for space-constrained designs
- AEC-Q100 qualified options available for automotive applications
- Flexible sequencing and soft-start control
Key Specifications
| Input Voltage | V |
| Output Voltage | V |
| Output Current | A |
| Switching Frequency | kHz |
| Efficiency | % |
| Quiescent Current | µA |
| Topology | — |
| Package | — |
| Operating Temp | °C |
| Protection | — |
Applications
Request Quote — In Stock, 100% New & Original, Full Warranty
BQ25121A: the charger, the buck and the reset button in one wearable part
The BQ25121AYFPR is a charge management device for wearables rather than a charger alone. Inside the 2.5 mm by 2.5 mm body there is a linear charger, a configurable 300 mA buck regulator, a load switch or a 100 mA LDO on the same pin, a push button monitor with an adjustable reset timer, and a simple voltage based battery monitor.
The quiescent current is the number that decides whether the product is usable. With the buck converter enabled and no load, the part draws about 700 nA from the pack. A smart watch that spends most of its life between charges cannot afford a management device that spends microamps doing nothing, and this is the class of part that made always-on wearables practical.
The charge side goes from 5 mA to 300 mA, with a battery regulation accuracy of 0.5 per cent and a setpoint adjustable from 3.6 V to 4.65 V in 10 mV steps. Termination current can be set as low as 500 microamps, which is what allows a 100 mAh watch pack to actually reach full rather than stopping at 20 per cent of its capacity short.
Key data for the BQ25121AYFPR
| Function | Wearable charge management: charger, buck, load switch, reset, monitor |
| Charge current | 5 mA to 300 mA |
| Voltage accuracy | 0.5 per cent, setpoint 3.6 V to 4.65 V in 10 mV steps |
| Termination | Configurable down to 500 microamps |
| Buck regulator | 300 mA, 2.5 V default, DCS-Control for light load efficiency |
| Quiescent current | 700 nA typical with the buck enabled and no load |
| Second rail | Load switch by default, or 100 mA LDO on the same pin |
| Input protection | 5.5 V overvoltage protection on a 20 V tolerant input |
| Push button | Wake up and reset with an adjustable timer, watchdog disabled by default |
| Monitoring | Simple voltage based battery monitor |
| Package | DSBGA, 25 balls, 2.50 mm by 2.50 mm |
| Temperature | Minus 40 to 85 C operating |
Body and ordering data
BQ25121AYFPR is the active production row: DSBGA YFP with 25 balls, 3000 pieces on a large tape and reel, SNAGCU finish, moisture level 1 at 260 C with no floor life limit, minus 40 to 85 C, marking BQ25121A. The .A and .B rows carry the same body and the same reel, so the revision letter in the string is the only marker of which die revision is in the bag.
Twenty five balls at 2.5 mm square is a fine pitch part, and the six external components the document quotes are the whole bill of materials for the charge and rail function. That count is the argument for the part: a discrete charger plus a buck plus a reset supervisor plus a monitor is eight to twelve components and three times the area.
The two rails and the button
The buck runs the processor at 2.5 V by default and can be set over I2C. The second rail on the LS/LDO pin is a load switch by default, which means it passes the battery voltage to a sensor or a display that has its own regulator, and it becomes a 100 mA LDO when the load needs a regulated rail. The choice is a register, not a component change.
The button input is a hardware function, not a software one. A long press resets the product, the timer is set by a register, and the part can wake the system from the button without the processor being involved. On a watch with no room for a separate supervisor and no spare pin, that saves both.
Where it fits in a build
Smart watches, fitness bands, health monitoring accessories and rechargeable toys. Any product with a pack under 200 mAh and a processor that has to run from a 2.5 V rail is in scope. The medical device components page covers the incoming inspection points that a health accessory build usually raises.
A product that needs more than 300 mA of charge current, or a pack above 2 cells, needs a different family. So does a product where the processor has to run from 3.3 V, because the buck default is 2.5 V and the range is set by the register map.
The sourcing side of this part is covered on the one stop BOM sourcing. For a wearable BOM with a fine pitch body and six passives, that page covers how we kit the whole line rather than the charger alone.
Questions we get on this code
Is 700 nA realistic on a real board? It is the part. The board leakage around it, especially the battery monitor divider and any pull-ups left enabled, is usually larger than the part itself.
Can the reset be disabled? The timer is configurable and the watchdog is disabled by default. A product that wants a hard reset on a long press sets the timer and leaves it.
What is the 20 V tolerant input for? Surviving a bad adapter or a hot plug transient, not operating at 20 V. The overvoltage protection acts at 5.5 V.
Does it need a thermistor? There is a TS input for pack temperature, and a wearable pack usually has one built in. Without it the charge has no temperature window, which on a product worn against the skin is worth keeping.