CAN Bus Transceivers and Controllers for Automotive and Industrial Networks
Product Specifications
Product Overview
A CAN node is two parts: a controller that formats the frames, and a transceiver that drives the differential bus. Plenty of microcontrollers include the controller, so only the transceiver is needed, but boards with a processor that has no CAN peripheral use a stand-alone controller such as the MCP2515 over SPI. Both cases are covered on this page.
The parts below span the three situations that come up most often: 5 V transceivers such as the MCP2551 and SN65HVD251 for equipment designed years ago, 3.3 V transceivers such as the SN65HVD230 that connect directly to a modern microcontroller, and galvanically isolated transceivers such as the ISO1050 for motor drives, battery systems and multi ground installations where a ground loop would otherwise destroy the interface.
All models are grouped into this single product, so a CAN node enquiry can cover the controller, the transceiver, the termination resistors and the isolated DC-DC supply for the bus side in one reply.
Electrical Specifications
| Parameter | Isolated CAN transceiver | 3.3 V CAN transceiver | 5 V CAN transceiver |
|---|---|---|---|
| Standard | ISO 11898-2 | ISO 11898-2 | ISO 11898-2 |
| Signalling rate | up to 1 Mbit/s | up to 1 Mbit/s | up to 1 Mbit/s (MCP2551 up to 1 Mbit/s) |
| Isolation | 2500 V RMS (DUB package), 5000 V RMS (DW package), transient immunity 50 kV/us typical | none | none |
| Loop delay | 150 ns typical, 210 ns maximum | not specified as isolation path delay | not specified as isolation path delay |
| Bus fault protection | -27 V to +40 V on the bus pins | -4 V to +16 V typical, +/-16 kV HBM ESD on bus pins | wide transient and short circuit range |
| Common mode range | -12 V to +12 V | -7 V to +12 V typical | -7 V to +12 V typical |
| Supply | 3.3 V on side 1, 5 V on side 2 (also available as 5 V / 5 V) | single 3 V to 3.6 V supply | 4.5 V to 5.5 V |
| Low power modes | driver dominant time out | standby mode at 370 uA typical (HVD230), sleep at 40 nA typical (HVD231) | slope control pin to reduce emissions |
Included Models and Order Codes
Order codes below include the package and the temperature code. The isolated parts are also listed with the isolation rating, because the DUB and DW packages do not have the same one.
| Model | Type | Rate | Supply | Package | Notes |
|---|---|---|---|---|---|
| ISO1050DUBR | Isolated CAN transceiver | 1 Mbit/s | 3.3 V / 5 V | SOP-8 (DUB) | 2500 V RMS isolation, fail safe outputs, 150 ns typical loop delay |
| ISO1050DWR | Isolated CAN transceiver | 1 Mbit/s | 3.3 V / 5 V | SOIC-16 wide (DW) | 5000 V RMS isolation version; ISO1042 is the current recommendation for new designs |
| SN65HVD230DR | 3.3 V CAN transceiver | 1 Mbit/s | 3 V to 3.6 V | SOIC-8 | Low current standby mode at 370 uA typical, up to 120 nodes on a bus |
| SN65HVD231DR | 3.3 V CAN transceiver | 1 Mbit/s | 3 V to 3.6 V | SOIC-8 | Ultra low current sleep mode at 40 nA typical |
| SN65HVD232DR | 3.3 V CAN transceiver | 1 Mbit/s | 3 V to 3.6 V | SOIC-8 | Version without the standby pin for fixed active operation |
| SN65HVD233DR | 3.3 V CAN transceiver | 1 Mbit/s | 3 V to 3.6 V | SOIC-8 | Loopback and diagnostic modes |
| SN65HVD234DR | 3.3 V CAN transceiver | 1 Mbit/s | 3 V to 3.6 V | SOIC-8 | Enable and standby control for bus managed designs |
| SN65HVD251DR | 5 V CAN transceiver | 1 Mbit/s | 4.5 V to 5.5 V | SOIC-8 | 5 V part for equipment designed around the earlier standard |
| SN65HVD1050DR | 5 V CAN transceiver | 1 Mbit/s | 4.5 V to 5.5 V | SOIC-8 | Alternate 5 V part with the standard pin out |
| MCP2551T-I/SN | 5 V CAN transceiver | 1 Mbit/s | 4.5 V to 5.5 V | SOIC-8 | Industry standard pin out, slope control pin for lower RFI, -40 C to +125 C |
| TJA1050T | 5 V CAN transceiver | 1 Mbit/s | 4.75 V to 5.25 V | SO-8 | Widely used automotive part, pin compatible with the MCP2551 footprint |
| TJA1042TK/3,1 | 5 V CAN transceiver | 1 Mbit/s | 4.5 V to 5.5 V | HVSON-8 (TK) | Standby mode version for permanent bus nodes |
| MCP2515T-I/ST | Stand-alone CAN controller | 1 Mbit/s | 2.7 V to 5.5 V | TSSOP-18 | SPI interface to any MCU, CAN 2.0B active, -40 C to +125 C |
| MCP2515T-I/SO | Stand-alone CAN controller | 1 Mbit/s | 2.7 V to 5.5 V | SOIC-18 | Same controller in the wide body SOIC package |
Key Features
Isolated And Non Isolated Options – Parts with 2500 V and 5000 V RMS barriers for drives and battery systems, and standard parts for equipment that shares a ground with the network.
3.3 V And 5 V Interfaces – Direct connection to modern microcontrollers at 3.3 V, and 5 V parts for boards that cannot be changed.
Low Power Modes – Standby at hundreds of microamps and sleep at tens of nanoamps, which matters for nodes that stay powered on a vehicle or a battery bank.
Bus Protection – Bus fault protection, cross wire protection, loss of ground protection, thermal shutdown and ESD ratings stated per part.
Stand-Alone Controller Option – The MCP2515 adds CAN 2.0B to any microcontroller over SPI, without changing the host processor.
Diagnostic Modes – Loopback and silent mode support for bring up and fault finding, on the parts that provide it.
Automotive Temperature Grades – Parts specified to +125 C where the node sits next to a motor, a charger or an engine bay.
Applications
Networks and boards that use these parts: A CAN node is normally quoted with the SUPERB PCB and SUPERB PCBA work we support, so the transceiver, the controller, the termination parts and the assembly come from one source.
Automotive And Telematics Modules – Gateway, body control and telematics units that have to keep the same interface parts through a long vehicle programme.
Motor Drives And Battery Systems – Isolated transceivers between a control board and a power stage, where a ground potential difference would otherwise damage the interface.
Industrial Automation And PLC Networks – Machine networks where several nodes share a bus over long cable runs and the network has to survive wiring faults.
Charging And Energy Storage Equipment – Battery management and charging racks with CAN links between modules and the system controller.
Sourcing and Cross-Reference
CAN parts are commonly specified by pin out rather than by part number, and several vendors share the same footprint. That makes substitution practical, but only if the electrical differences are known: the common mode range, the bus fault voltage, the low power mode pins and the loop delay all differ, and on an isolated part the package decides the isolation rating (the same ISO1050 family is 2500 V RMS in the DUB package and 5000 V RMS in the DW package).
Where a part has been superseded, we say so. The ISO1050 is a good example: it is still sourced and still used, but the vendor recommends the ISO1042 for all new isolated CAN designs, so we state that in the quote rather than letting a new design move onto a mature part without knowing it. Related interface parts for the same boards, such as the SN65HVD3082E and SN65HVD75 RS-485 transceivers, are also sourced on request.
For volume builds, SUPERB Assembly support covers the SMT assembly of the interface board.
Q: Can you supply a pin-compatible CAN transceiver alternative when the original part is discontinued?
A: Yes. Send the part number and the quantity and the SUPERB Tech sales team will confirm availability and a pin compatible alternative where one exists.
Why Source CAN Interface Parts from Superb Automation?
- Interface Part Focus: CAN and RS-485 transceivers and controllers supplied as a group, with the pin out and the protection ratings of each part compared.
- Isolation Rating Accuracy: The isolation voltage is quoted per package, because that is how the part is actually specified.
- Superseded Part Guidance: Where a vendor recommends a newer device for new designs, the quote says so, and both parts are offered.
- Automotive Grades: High temperature parts for nodes next to motors, chargers and other heat sources.
- Network Level Kitting: Transceivers, controllers, termination resistors, common mode chokes and isolated supply parts for the same bus quoted together.
- Reply With Condition Stated: Marking, packing and condition on the quote, which matters for interface parts that are often pulled from scrap boards.
Related Product Families
This page is part of the component range we supply for industrial, telecom, medical and defence builds. Continue with: Multi-Function ICs, MCU and Embedded Processors, Components, Component Sourcing and Supply.