Contact Us
  • Home
  • BLOG
  • How Far Apart Should RF Ground Vias Be?

How Far Apart Should RF Ground Vias Be?

Space ground vias a twentieth of the guided wavelength at the highest frequency on the board, and use the guided wavelength rather than the free-space one. On FR-4 class laminate with a dielectric constant of 4.2 that is 1.22 mm at 6 GHz, 0.73 mm at 10 GHz, 0.30 mm at 24 GHz, 0.26 mm at 28 GHz and 0.095 mm at 77 GHz. Above about 12 GHz that pitch is smaller than the pad of a mechanical via, so the fence stops being a spacing question and becomes a structure question.

The error that shows up most often is the wavelength itself. At 10 GHz the free-space wavelength is 30 mm, and a twentieth of it is 1.5 mm. The guided wavelength in Dk 4.2 is 14.6 mm and a twentieth is 0.73 mm. The difference is exactly the square root of the dielectric constant, and it is the difference between a fence that works and a fence that looks right.

Why a twentieth

Two ground planes with a dielectric between them form a parallel plate waveguide. Energy launched into that sandwich travels sideways, and if the planes are large enough the cavity also resonates where a dimension equals a multiple of a half wavelength. A fence of ground vias cuts one large cavity into a grid of small ones, and each cell has a cutoff below which energy cannot propagate across it:

cutoff = c / (2 x spacing x square root of Dk)

With 5 mm between vias on Dk 4.2 the cutoff is 14.6 GHz. With 1 mm it is 73 GHz. A twentieth of the guided wavelength puts the cutoff of the cells roughly a decade above the operating band, which is why the same number appears in application notes from different vendors: at that spacing the fence is far from its own limit.

What one row buys, and what the second row buys

A single row of ground vias along a trace, connected on every ground layer, gives roughly 20 to 30 dB of isolation below the first resonance of the fence. Where a module needs 35 dB between two channels and the pitch cannot be halved, a second row staggered by half a pitch is the cheaper answer: it interrupts the straight path between the gaps without doubling the via count along the length.

Two other dimensions decide whether the fence works at all. The distance from the trace matters as much as the pitch: keep the row at three to five trace widths from the line, which on a 0.298 mm wide 50 ohm microstrip is 0.9 to 1.5 mm. And the antipad around each via has to stay small enough that the plane keeps its copper between vias, otherwise the row is a series of holes in a mesh rather than a wall.

Where the pitch stops being buildable

A via pad is the drill plus two annular rings plus twice the layer-to-layer registration. With our published 3.5 mil ring on 1 oz copper and 0.025 mm of registration, a 0.30 mm drill gives a 0.528 mm pad; with a 0.06 mm allowance the same drill gives 0.598 mm. Compare that with the pitch the rule asks for:

FrequencyGuided wavelengthOne twentiethTotal pad at 0.30 mm drill
6 GHz24.4 mm1.22 mm0.528 mm, fits
10 GHz14.6 mm0.73 mm0.528 mm, 0.20 mm copper between pads
15 GHz9.8 mm0.49 mm0.528 mm, pads would merge
28 GHz5.2 mm0.26 mm0.528 mm, not possible
77 GHz1.9 mm0.095 mm0.528 mm, not possible

The crossover sits near 11.6 GHz on Dk 4.2. Below it, a single row of 0.30 mm mechanical vias at a twentieth of the guided wavelength is an ordinary board. Above it there are three options and only three: a smaller via, which moves the crossover up but not to 77 GHz (a 0.20 mm laser drill gives a 0.428 mm pad), a tenth of the wavelength with two staggered rows, or a fence that follows the current path instead of the whole trace.

Three things that go wrong

The free-space wavelength. A fence laid out at 1.5 mm for a 10 GHz board is twice as open as the rule asks for. The board can still pass a bench check, and the leakage shows up as crosstalk between two channels.

A fence that stops at the corner. Energy goes around the end of a row. Corner vias, a row that wraps the bend on the layer where the trace leaves the fenced area, and edge stitching where the trace crosses the boundary are part of the fence. Shield cans have the same problem: a perimeter with no stitching inside leaves a cavity of its own.

A via that skips a ground layer. A ground via that ties planes one and three but stops short of the second is a stub, and a stub is an antenna. The fence only works when every ground layer is tied at that point.

A fence is not a shield

On a 28 GHz board the fence decides where energy goes, not whether it is attenuated. Radiation from an open trace end, a connector launch or a slot in the ground still leaves the board, and the fence only changes the impedance the wave sees at the boundary. That is why a board can pass its own isolation check on the bench and still fail a radiated emissions test: the fence was never asked to stop radiation, only to stop the parallel plate mode that feeds it.

What SUPERB PCB controls on an RF build

Frequency range 500 MHz to 77 GHz, line and space down to 0.05 mm with 0.035 mm fan-out on HDI, impedance held to plus or minus 5% with plus or minus 2% on critical nets, layer-to-layer registration 0.025 to 0.06 mm, laser drills 0.075 to 0.15 mm and mechanical drills from 0.15 mm, aspect ratio 10:1 standard and 25:1 on the high layer line, back drill stub of 0.25 mm or less, and a TDR coupon on every panel.

The geometry that decides spacing, cutoff and isolation is the drill file, the plating and the registration, and those are what we hold. Isolation in decibels and the first resonance of a fence are measured on a fixture or in a chamber, by the customer laboratory or by a partner RF laboratory, not on our line. The build side is on RF and microwave PCB and RF PCB, and the laminate choice that sets the guided wavelength is in Rogers, PTFE or FR-4. SUPERB Tech checks the fence pitch against the laminate Dk on every RF order, because the same drawing on a different Dk is a different fence.

What to send with the order

Highest frequency including the third harmonic near any non-linear part, the Dk of each dielectric in the stack, the isolation you need and between which two regions, the smallest via the layout can accept, whether microvias are allowed, which layers are ground, and whether a shield can lands on the fence. Those seven items decide the pitch before the drill file is released.

Need a quote or a review of your stack against these limits? pcba@superb-tech.com · WhatsApp +86 133 9608 1443