We build 60 GHz mmWave radar boards and modules to print: AiP carrier boards, RF front-end boards and the control board behind them. You send the Gerber, stack-up, BOM and test specification; we return assembled, inspected and traceable units, from first article through volume.
What a 60 GHz radar board actually contains
Most 57 to 64 GHz products are three boards or one board with three very different jobs:
- The AiP carrier. The antenna-in-package sensor sits on a keep-out area with matched feed, ground stitching and a thermal path. Everything within a few millimetres of the aperture affects the radiation pattern.
- The RF front-end. Microstrip and coplanar structures on low-loss laminate, often hybrid with FR-4 to keep cost down. This is where impedance control decides whether you get the range you simulated.
- The control and power board. MCU, PMIC, level shifting, connectors, protection. Ordinary digital work, except the noise it injects can wipe out a weak radar return.
Where 60 GHz breaks a normal SMT line
Five failure modes account for most of the yield loss we see on incoming radar designs:
| What goes wrong | What the customer sees |
|---|---|
| Impedance off by 10 percent | Range drops a few metres, detection becomes intermittent in the field, and the lab report still passes at room temperature. |
| PTFE or hydrocarbon laminate run on the FR-4 line | Drill smear, delamination after reflow, dielectric thickness drift, insertion loss creeps up across the batch. |
| Copper or solder mask inside the antenna keep-out | Pattern distortion and a few dB of gain lost. Nothing looks wrong on the board. |
| Conformal coating over the radiating aperture | Frequency shift and loss. Often discovered only after the units are potted and sealed. |
| Shield frame not coplanar before reflow | Lid sits on paste, one edge lifts, the unit passes visual inspection and fails EMC later. |
How we control it
- Stack-up confirmed before tooling. We check your layer stack and impedance targets against the laminate datasheet and our process capability, and we tell you if a target is not achievable on our line before you pay for tooling.
- Material routing. PTFE and hydrocarbon laminates get their own drill, plasma and bake cycles. They are never mixed into an FR-4 panel.
- Keep-out discipline. Copper, mask and coating keep-outs are built into the stencil and the coating program, not left to the operator to remember.
- Placement and inspection. 0201 passives and 0.35 mm pitch connectors are routine. The AiP sensor and its matching network are checked after placement and again after reflow.
- Shielding. Frames are placed and checked for coplanarity before the reflow that joins them.
- Coating and potting. Conformal coating and selective potting in house, masked at antennas, connectors and test points.
Inspection and test
| Stage | What is done |
|---|---|
| Solder paste | SPI on fine-pitch and BGA apertures |
| Placement | AOI on critical parts |
| Reflow | Profiled per board, profile recorded and kept with the serial number |
| After reflow | AOI, X-ray on BGA and QFN for void and alignment, visual to IPC-A-610 Class 2 or 3 |
| Electrical | ICT and boundary scan, firmware programming, functional test against your golden sample |
| Traceability | Serial number linked to panel, stencil, paste lot, reflow profile, operator and test record |
RF measurement, stated plainly. DC, digital and functional test are in house. RF characterisation — output power, frequency accuracy, phase noise, sensitivity, radiation pattern — is run through a qualified RF laboratory or on a fixture you supply, and an OTA chamber can be installed in house when programme volume justifies it. Before we quote, we put in writing which measurements we perform and which we do not. You will not discover a test gap at shipment.
Design and build under one contract
Many radar projects arrive with the architecture and the BOM fixed but no schematic. If that is your situation, the design phase can sit under the same contract: schematic, power and protection, sensor and interface integration, 60 GHz layout to the silicon vendor's reference rules, firmware, DFM and DFT review. The engineering team assigned to your project works under our NDA and our project management, and SUPERB remains the single party accountable for schedule, quality and warranty.
Every project-specific deliverable produced under the paid scope belongs to you: editable schematic and layout source files, Gerber and drill files, BOM, CPL, assembly drawings, firmware source and test documentation. No licence fee, no retention.
From prototype to volume
| Step | What you get |
|---|---|
| DFM review | Written report within 48 hours: everything in your files that will cost yield, and the fix. |
| Tooling and first article | Stencil, fixture, program and reflow profile built and verified on the first panel; dimensional, X-ray and functional report before volume release. |
| Volume | Same line, same program, same fixture as the first article. No silent process change. |
| Change control | Any BOM, stack-up or process change re-enters at first article, not at shipment. |
Where these boards go
- Presence and occupancy — lighting, HVAC, meeting rooms, where PIR loses a person who sits still.
- Vital signs — non-contact breathing and heart rate for elder care and sleep monitoring.
- Gesture and interaction — touchless control of appliances and displays.
- In-cabin monitoring — child presence detection, seat belt reminder, driver monitoring.
- Robotics and AGV — short-range obstacle sensing where a camera struggles in dust or darkness.
- Level and proximity — short-range measurement in tanks, bins and dispensers.
What we need from you
- Gerber, stack-up drawing, BOM with approved alternates, assembly drawing with reference designators.
- Test specification, golden sample and fixture, or approval for us to build the fixture.
- Handling notes: what must not be coated, cleaned, reflowed twice or probed.
Frequently asked
Can you assemble an AiP sensor without touching the antenna area?
Yes. The keep-out is built into the stencil, the placement program and the coating program, and it is checked on the first article before volume starts.
Which laminates do you run for 60 GHz?
PTFE and hydrocarbon laminates from the main suppliers, hybrid with FR-4 where the design allows it. Send the stack-up and we will confirm what is achievable on our line, including impedance tolerance.
What is the minimum order?
No minimum on assembly. Prototype quantities start at five units; the price break is in the PCB panel and the setup, not in a forced quantity.
Can you do the design if we only have requirements and a BOM?
Yes, under the same contract, with the deliverables owned by you. That is how a large share of our radar projects start.
How do you handle do-not-substitute parts on allocation?
We tell you before the build, not after. You get the alternatives with the trade-off written down, and nothing is substituted without your written approval.
Send the files