A panel of twenty four boards arrives with three positions crossed out in ink. The line runs the panel, places parts on all twenty four, and the operator finds the three dead boards at the end of the run. Parts are lost, rework time is lost, and the delivery is three boards short of the quantity on the order. Nothing was hidden. The marking simply never reached the machine that places the parts.
An x-out is a board position on a panel that failed bare board test or inspection and will not be shipped as a working unit. Handling it well is a question of marking, mapping, counting and delivery, and all four are cheaper to agree before the panel is built than to argue about after it.
Why the marking exists
Bare board test, AOI and final inspection work on a panel, not on a single board. When one position fails, the panel is still worth building and still worth shipping, as long as everyone downstream knows which position is dead. The mark is that message. Without it the panel looks uniform, and every process after test treats the failed position as good.
Two different readers have to see the mark: the operator who inspects and packs, and the placement machine that decides where to put parts. A mark that only a person can read works for the first and fails the second.
Marking methods and what each one survives
| Method | How it reads | Survives | Risk |
|---|---|---|---|
| Ink dot or cross | Operator, camera with bad mark recognition | Packing, manual assembly | Faint ink missed by the camera, or ink on a pad |
| Scribed X on the surface | Operator | Packing | Scratches near traces, no machine read |
| Drilled hole through the board | Operator, mechanical stop | Packing, some fixtures | Cannot be used where the hole lands on a test pad |
| Laser mark or label | Camera, barcode reader | Automated lines with a map file | Needs the map file to match the label |
| Board removed from the panel | Nobody, the gap is visible | Packing, manual lines | Panel stiffness drops, rails may not clamp |
The most common arrangement is a black ink dot on the failed position plus a written panel map, and a placement program that reads the dot as a bad mark. The dot has to sit where the camera looks, clear of pads and clear of the fiducial search area, or the machine reads nothing and places parts anyway.
What the assembly line needs
Three things decide whether the line can skip a dead board without slowing down:
- A readable bad mark in a fixed position on every panel, not a mark added by hand in a different place each time.
- A panel map that gives the position number of each x-out, so the count and the program agree.
- A rule for what happens to the skipped position. Either the machine skips placement, or the board is populated and scrapped. The first saves parts, the second saves program time. The choice belongs to the buyer.
Where the assembly house runs the same panel repeatedly, the map becomes a program input rather than a note. That is why the map should travel with the panel rather than arrive by email after the fact.
Counting, pricing and delivery
The single most common dispute is not the marking, it is the count. "One thousand boards" can mean one thousand good boards, or one thousand positions of which some are x-outs. Write the basis into the order:
- Quantity counted in good boards only, with x-outs replaced so the panel yield still reaches the number.
- Quantity counted in positions, with x-outs shipped in place and deducted at invoice.
- A maximum x-out rate per panel, above which the panel is rebuilt at the board house's cost.
Delivery follows from the same choice. X-outs left in the panel keep the panel rigid and the rails usable. X-outs removed lighten the panel and make the shortage visible at once, but a panel with several positions missing can flex enough to trouble paste printing. For thin boards, leaving them in is usually the safer default.
How SUPERB PCBA handles x-outs
Panels are built to print at the PCB end and assembled at the SMT end, so the map is written at test and read at placement inside one flow. Panel size runs to 622 by 1092 mm, finished thickness 0.6 to 3.2 mm, warp held to 0.75 percent or better so a panel with x-outs still sits flat on the printer. V-cut at 30, 45 or 60 degrees and routed tabs are both available, and the choice interacts with x-outs: a routed panel tolerates a missing position better than a V-cut panel, where the remaining web carries the stiffness.
Assembly runs on seven SMT lines with 3D SPI, 3D AOI, X-ray and ICT or flying probe, and the bad mark is read before placement rather than after. Each panel ships with the map that matches the marking on it, so the count on the packing list and the count in the program are the same number. Panel rules sit on the panelization page, and what happens after assembly at depanelization methods.
One point that catches buyers out: the fiducial and the bad mark compete for the same camera time. If the bad mark sits inside the fiducial search window, the machine may lock onto it as a reference. Keep them apart, as described under fiducial mark requirements.
What to put in the purchase order
- Marking method, and the position of the mark on the panel.
- Whether a map file is required, and in what format.
- Count basis: good boards or positions.
- Maximum x-out rate per panel, and who pays for a panel above it.
- Whether x-outs ship in the panel or are removed.
Questions buyers ask
Can every position on a panel be an x-out?
No. A panel with no good boards is scrap, and most programmes set a ceiling well below that. The ceiling belongs in the order, because it decides when the panel is rebuilt rather than shipped.
Does an x-out affect the boards next to it?
Not electrically. Mechanically it can, if the missing position was carrying panel stiffness, which is why removal is decided per board thickness and panel shape rather than by habit.
Who marks the x-out, the board house or the assembly house?
The board house, at the test that found the failure. Marking at assembly means the panel travelled with a known bad board and nobody recorded it, which is the case the map exists to prevent.
Next step
Send the panel drawing and the quantity basis you work to. SUPERB PCBA returns a marking rule, a map format and a count rule that fit the panel, so the x-outs are settled at the drawing stage and the delivery matches the order. Quotes include the x-out terms rather than leaving them to the first shipment.