Contact Us

AOI False Call Reduction

AOI False Call Reduction

A panel of two hundred boards leaves the oven and reaches the optical station. The station reports four hundred and twelve defects. The engineer reading that number already knows most of it is noise: the same pad flagged on every board, a shadow under a tall connector, a fillet the camera cannot see from that angle. Clearing the list takes an operator two hours, and the one real defect, if it exists, sits inside the same list.

AOI false call reduction is the work of moving a station from that list to a short one that can be trusted. It is part program, part line stability, and it runs in two directions at once, because every setting that removes a false call also accepts more real ones.

What a call actually compares

An inline optical station does not know what a good joint looks like. It compares what the camera sees against a reference built from the CAD centroid and pad data, from a golden board, or from a library of accepted images. A call is raised when the difference between the image and the reference passes a threshold.

Three things therefore decide the call rate: the reference, the threshold and the image. A program can be correct on paper and still call all night, if the image changes from board to board because the panel never sits flat.

Where false calls come from

What the station reportsWhat is actually behind itWhat to change
The same pad flagged on every board, and the joint looks rightReference taught from a library image of a different pad shape, or never re-taught after a paste changeRe-teach the library from boards built on this line
Calls only on one side of the panelPanel not seated, support pins missing under that areaFix the support, run a new first article
A tall part shadows its neighbourCamera angle and lighting cannot reach the jointAdd a second view, or move that check to X-ray
Chip parts called as shifted after every printDeposit off centre, printer driftingRead the print data first, touch the station last
Calls start after a component changeNew body colour or height against the old library entryUpdate the part entry, keep the old one for the running build
An entire panel flaggedWrong program, or the panel loaded in the wrong orientationLink the program to the barcode at load

The escape side of the same dial

Every threshold moved to reduce calls also accepts more real defects. The class the board is sold against decides where that line sits, and it decides it per feature, not per board: IPC-A-610 Class 2 allows a fillet shape that Class 3 rejects, and a program tuned to Class 3 limits on a board sold as Class 2 will call good work all shift.

The class has to be written into the program and into the defect list behind it, not held in the operator's head. When it is, a call means one thing. When it is not, the call is cleared by habit, and that habit is how an escape ships.

Noise at the printer arrives as calls at the station

Most of what the station complains about was decided two stations earlier. Paste volume spread widens, the deposit edge moves, and a shift call follows. We measure the deposit at the print with 3D SPI, so the paste is judged where it is made and the optical program is not asked to police the printer.

The same logic runs the other way. A station that reports nothing is not a clean line; it is a station whose thresholds were turned down until the list emptied.

How SUPERB PCBA sets the program

We run 3D optical inspection after reflow and a separate station after wave or selective solder, because the two processes fail in different ways and one program cannot hold both. The program is built and tuned on the first article from the machine that will run the order, with the customer's class and the customer's defect list in front of the engineer.

Seven SMT lines place down to 01005 (0.4 x 0.2 mm) at up to 40,000 CPH, so the same station has to read a 01005 chip and a 55 mm connector body on one panel. Where a joint sits under a package, X-ray View-x1800 takes over in 2D or CT, and the optical station is not asked to guess.

The equipment side is on the post reflow inspection station page. Where each method sees and where it does not is covered in optical versus X-ray inspection, and the print side in solder paste inspection.

What holds over a long run

Three things keep a tuned program tuned. The panel is supported the same way on every run, with tooling pins and no tape. The paste is measured at the print, so drift is caught before it becomes a call. And the program names who owns a change, so an engineering change order re-teaches the affected features instead of leaving the old reference to collect calls for months.

The first article record is what makes this checkable. It shows the call list on the panel that was built first, and it can be compared with the call list on the last panel of the same order.

Questions buyers ask

Can a false call rate be quoted in advance?

No. It depends on the board, the part mix, the coating and the class. What can be quoted is the process: tuned on the line, class written in, re-taught after a change.

Does a lower call rate mean a better line?

Not on its own. Ask for the escape rate as well, and ask how the program is verified after a change.

Is X-ray needed if the optical program is set well?

For joints under a package, yes. The camera reads the surface, and a ball array sits under the body.

Next step

Send the BOM, the Gerber set and the class the board is sold against. The inspection plan comes back with the checks per side, the reference each one uses, and the point where X-ray takes over.

Actual product photos available on request