Contact Us
  • Home
  • PCBA
  • 48 V Power Distribution Board PCBA for Mobile Robots

48 V Power Distribution Board PCBA for Mobile Robots

48 V power distribution board PCBA for robots. Multi-rail conversion, eFuse and hot-swap protection, per-rail current monitoring, 6-layer 3 oz copper.
quote now

Product Specifications

Product Overview

A mobile robot runs from a 48 V battery and needs 24 V for sensors, 12 V for fans and lights, 5 V for compute and 3.3 V for logic, with each rail protected against a short on the load side and against a hot swap that pulls a large inrush.

The board is a power tree with protection, not a regulator module. The failure modes that matter are a stalled motor dragging the 48 V bus down, a shorted sensor cable, and a battery plugged in while the robot is powered.

We build it on 6 layers with 3 oz copper on the high-current paths, eFuses with adjustable current limit per rail, and a current monitor that reports to the robot controller over CAN or I2C.

Key Specifications

Layer count6 layers, 1.6 mm
Copper weight3 oz outer, 2 oz inner
Input36 to 60 V DC, reverse polarity protected
Outputs24 V / 8 A, 12 V / 10 A, 5 V / 8 A, 3.3 V / 3 A
ProtectioneFuse per rail, adjustable current limit
InrushHot-swap control, dv/dt limited
MonitoringPer-rail current and voltage, CAN or I2C
Efficiency targetAbove 92% at 50% load
Operating temperature-20 to +70 °C
CoolingThermal vias and copper planes, no fan
CoatingSelective, connectors masked
Test coverage100% ICT, load sweep, short-circuit trip test

PCBA Assembly Challenges

  • A short on a 24 V rail must trip the eFuse in microseconds without taking down the compute rail; the current-limit threshold and the response time have to be tuned per rail.
  • Hot plugging a battery into a robot with large input capacitance produces an inrush that can weld connector contacts; the dv/dt network is sized for the worst-case capacitance.
  • The 48 V input is also the motor bus, so the converter input sees switching noise from the drives; input filtering has to be placed before the sense point.
  • Per-rail current monitoring needs Kelvin connections at the shunt, otherwise the reported current drifts with solder resistance.

Test Strategy

The board is tested as a power system, with load sweeps and fault injection:

  • In-circuit test on all nets, including the shunt Kelvin connections.
  • Load sweep on every rail from 10% to 100%, with efficiency and ripple recorded.
  • Short-circuit trip test on each rail, with trip time and recovery behaviour logged.
  • Hot-swap test: battery connected with the robot powered, input current waveform captured.
  • Thermal soak at 70 °C for 1 hour at 80% load.

PCB Manufacturing Difficulty

3 oz copper carrying 8 to 10 A per rail needs wide traces and multiple vias per layer transition; a single via rated at 2 A becomes the hot spot in a 10 A path.

The converter loop area must stay small; a long input loop turns the board into a radiator that fails conducted emissions.

Selective coating keeps the connectors and the shunt test points clean, because coating on a Kelvin pad changes the measured resistance.

Applications

  • Autonomous mobile robots with 48 V batteries and multiple payloads
  • Humanoid robots that distribute power to torso, arms and head
  • Robot docks and charging stations that switch between charge and run
  • Agricultural robots with pumps, fans and sensors on one bus
  • Inspection robots with lights and cameras on separate rails
  • Test benches that emulate the robot power tree

Why Superb Automation

  1. Engineering review before tooling: stack-up, copper weight, creepage and assembly sequence are checked against the drawing before the first panel is released.
  2. PCB fabrication and PCBA assembly held to one schedule, so the bare board and the assembly do not slip against each other.
  3. Incoming component inspection with X-ray and XRF on reels, plus traceability records per lot.
  4. Selective conformal coating, potting and staking available in the same build, not subcontracted to a third party.
  5. Functional test fixtures built to your specification, with DC, digital and boundary-scan coverage reported per unit.
  6. Quotation from one BOM and one drawing set, with DFM feedback returned before you commit to a build.