Isolated gate driver board PCBA for 1200 V SiC and IGBT modules in PCS. 3 oz copper, thermal vias under the driver, 100% functional test with double-pulse verification.
quote now

Product Specifications

Product Overview

The gate driver board is the part of a PCS that decides switching loss, dead time and fault behaviour. It takes the PWM commands from the controller, level-shifts them across an isolation barrier, and drives the SiC or IGBT module with enough peak current to switch in tens of nanoseconds.

Electrically this is a fast, noisy board. dv/dt at the module terminals reaches 50 kV/us, the driver ground bounces with the emitter inductance, and the DESAT comparator has to distinguish a real short circuit from the noise of a normal switching event. Layout, not part choice, sets whether that works.

We build the board on 6 to 8 layers with 3 oz outer copper, thermal vias under the driver IC, and a separate return path for the gate loop that never shares copper with the DC bus sense. Isolation is 1200 V reinforced with a 10 mm creepage slot milled or routed under the isolator.

Key Specifications

Layer count6 to 8 layers, 1.6 to 2.0 mm
Base materialFR-4 high Tg, CTI 600
Copper weight3 oz outer, 2 oz inner
Isolation1200 V reinforced, 10 mm creepage
Peak gate currentDesign dependent, up to 10 A per channel
SwitchingSiC MOSFET or IGBT, dv/dt to 50 kV/us
ProtectionDESAT, active Miller clamp, soft turn-off
Thermal vias0.3 mm drilled, filled and capped under driver
Operating temperature-40 to +105 °C
ConnectorsPress-fit or board-to-board, low inductance
CoatingSelective polyurethane, 50 um
StandardsIEC 62477 and IEC 61800 documentation pack
Test coverage100% ICT, isolation, double-pulse on sample basis

PCBA Assembly Challenges

  • The gate loop inductance is set by the distance from the driver output to the module pin and back; every millimetre of loop adds ringing that shows up as overshoot at the module.
  • DESAT blanking has to be tuned per module: too short and the drive trips on normal switching noise, too long and a real short circuit destroys the module before the trip.
  • Thermal vias under the driver must be filled and capped, otherwise solder wicks into the via during reflow and the driver sits on a void.
  • 3 oz copper with fine spacing needs etch compensation; an under-etched gate trace changes the drive impedance and the switching waveform.

Test Strategy

The board is tested at the driver level, then verified on a double-pulse bench before the lot is released:

  • In-circuit test including isolation resistance between primary and secondary.
  • Functional test with a simulated module load: gate voltage levels, dead time, DESAT trip threshold.
  • Double-pulse switching test on the first articles, with overshoot, ringing and turn-off energy recorded.
  • Thermal soak at 105 C for 2 hours, then repeat the functional test.
  • Visual and X-ray check on the thermal via field under the driver.

PCB Manufacturing Difficulty

3 oz copper and 6 mil spacing on the same layer limit how much routing fits between the driver and the module; we plan the power and gate layers first and keep the sense layers free of switching current.

The creepage slot under the isolator is a mechanical feature as much as an electrical one: it must be routed before lamination planning, because a slot that crosses a prepreg window delaminates in thermal cycling.

Filled and capped vias under the driver add a planarisation step; without it the driver sits 20 to 30 um high and the solder joints crack in thermal cycling.

Applications

  • Central inverters for utility-scale storage in the 1 MW to 5 MW class
  • String PCS for commercial cabinets from 50 kW to 250 kW
  • Bidirectional DC-DC stages between the battery bus and the DC link
  • Solid-state transfer switches in storage-backed microgrids
  • EV charger power modules that share the same SiC topology
  • Test benches that characterise SiC modules at rated current

Why Superb Automation

  1. Engineering review before tooling: stack-up, copper weight, creepage and assembly sequence are checked against the drawing before the first panel is released.
  2. PCB fabrication and PCBA assembly held to one schedule, so the bare board and the assembly do not slip against each other.
  3. Incoming component inspection with X-ray and XRF on reels, plus traceability records per lot.
  4. Selective conformal coating, potting and staking available in the same build, not subcontracted to a third party.
  5. Functional test fixtures built to your specification, with DC, digital and boundary-scan coverage reported per unit.
  6. Quotation from one BOM and one drawing set, with DFM feedback returned before you commit to a build.