14-Layer 6-Step HDI — High-Voltage Power Transformer Module
Product Specifications
14-Layer 6-Step HDI — High-Voltage Power Transformer Module
14-layer 6-step HDI · 70 μm heavy copper · PTFE+FR4 · 2.5 mm · AC withstand > 2000 V · ENIG · Layer offset < 30 μm · Stacked laser via · Build-to-print from Gerber
Product Specifications
| Parameter | Value |
|---|---|
| Product type | High-voltage power transformer module PCB (电源变压模块) |
| Layer count | 14 layers, 6-step HDI (14层6阶) |
| Via structure | Laser blind stacked via (激光盲孔叠孔) · 6 sequential build-up steps |
| Finished board thickness | 2.5 + 0.25 mm |
| Base material | PTFE + FR-4 hybrid lamination — high-voltage insulation |
| Copper thickness | 70 μm inner layer + 70 μm outer layer (heavy copper throughout) |
| Surface finish | ENIG — Electroless Nickel / Immersion Gold (化金) |
| Dielectric withstand | AC > 2,000 V — high-voltage rating |
| Layer-to-layer registration | Offset < 30 μm (层间偏移) |
| Any-layer registration | Offset ≤ 50 μm (任意层偏) |
| Application | Power transformer module (电源变压模块) |
14-Layer 6-Step HDI Stack-Up
6 sequential build-up steps — six lamination + laser drill + copper plate cycles
Core stack: L3–L12 10-layer core with PTFE+FR-4 hybrid laminate
Build-up Step 1: L2–L3 and L12–L13 blind via + plate
Build-up Step 2: L1–L2 and L13–L14 blind via + plate
Steps 3–6: Additional staggered and stacked blind vias for high-density interconnect
All vias copper-filled — stacked via chain through multiple build-up layers
70 μm copper on every layer — heavy plating maintained through all 6 build-up cycles
High-Voltage Design — AC > 2,000 V
PTFE + FR-4 hybrid laminate — PTFE for high-voltage insulation, FR-4 for structural rigidity
AC withstand > 2,000 V — tested per IPC-TM-650 2.5.7, no breakdown or flashover
Creepage distance control — trace-to-trace and trace-to-plane spacing designed for HV clearance
Partial discharge resistant — void-free lamination, no air gaps in high-field regions
70 μm thick copper — high current capacity for transformer primary and secondary windings
2.5 mm board thickness — sufficient dielectric thickness for HV isolation between layers
70 μm Heavy Copper Throughout
Inner layers: 70 μm (2 oz) — transformer winding traces, high-current bus
Outer layers: 70 μm (2 oz) finished — component pads, power terminals
Uniform copper across all 14 layers — balanced stack-up, no warpage from asymmetric copper
Pulse-reverse plating — uniform thickness across high-aspect-ratio traces and vias
Thermal conductivity — thick copper planes spread heat from transformer core losses
Registration Precision — ≤ 50 μm Any Layer
Layer-to-layer offset < 30 μm — between adjacent layers
Any-layer cumulative offset ≤ 50 μm — L1 to L14 total registration error
6-step process control — each lamination + drill cycle aligned to fiducial targets
Laser Direct Imaging (LDI) — ± 15 μm per layer, X-ray alignment per build-up step
Critical for HV isolation — misregistration can reduce creepage distance, compromise voltage rating
6-Step Stacked Via Technology
Laser-drilled blind vias — UV laser, 75 μm via diameter through 50 μm dielectric
Stacked via chain — L1→L2→L3→L4 direct copper path through four build-up layers
Copper-filled + planarized — flat surface for next build-up step, via-in-pad capable
Plasma desmear — PTFE via wall activation between each build-up cycle
X-ray verification per step — stacked via alignment checked before next lamination
ENIG Surface Finish
Ni 3–6 μm / Au 0.05–0.12 μm — IPC-4552 compliant
Flat pad surface — coplanarity for power transistor and transformer component mounting
Wire-bond compatible — gold wire bonding on ENIG pads for power die attachment
Multiple reflow cycles — module assembly + customer board-level assembly
Manufacturing Notes
Build-to-print from Gerber RS-274X — HV test coupon included on production panel
Hi-pot test 100% — AC > 2,000 V, 60 s, per IPC-TM-650 on every board
100% flying probe electrical test — continuity + isolation, all nets
100% AOI — 2 μm resolution, all 14 layers
X-ray per lot — stacked via alignment, copper filling void check
Cross-section per lot — via plating, dielectric thickness, copper thickness, registration verification
Lead-free RoHS compliant — ENIG, PTFE+FR-4 laminate, no lead
Gerber file review & DFM → pcba@superb-tech.com
Superb Automation Co., Limited · High-Voltage HDI Transformer Module · Wuxi + Huizhou, China
Canonical URL: to be assigned